VA-6100P85
8-zone Amplifier
Learn more
Descriptions:
VA-6100MS changeover integrates the main and standby power amplifier conversion functions, ground detection, open circuit detection, and short circuit detection of the speaker circuit. It is also compatible with three-wire and four-wire volume controller wiring. It does not require additional wiring and power supply, and has 8-channel programmable dry or wet node trigger inputs and 8-channel programmable online output signals. The controller can be combined with Class D digital amplifiers and traditional analog amplifiers to build a user audio amplification system, providing a safe, stable, and economical solution for the system.
| AC power input voltage | ~ 220V ± 15 % , 50-60Hz |
|---|---|
| AC power input current | < 1 A ( including 4-wire forced output ) |
| DC power input voltage | DC24V , 19-30V adaptive |
| DC power input current | < 6.25 A |
| Maximum power consumption | 150W |
| Number of output partitions | Up to 8 |
| Output voltage | 100V |
| Output type | Transformer-less bridge-tied output |
| Output power | 500W ( maximum output of a single zone ) |
| Maximum output power | 8×500W |
| Strong cutting type | 3-wire and 4-wire |
| 4-wire forced output voltage | 24V |
| Amplifier status detection time | < 1 S |
| Partition detection status | Short circuit, open circuit, short circuit to ground |
| Partition detection time | < 1 S |
| Line input number | 8-way |
| Line input sensitivity | ± 385mV (balanced) |
| Line input impedance | 20KΩ |
| 8-channel relay programmable output | Short circuit, no voltage |
| 8-channel programmable trigger inputs | Short-circuit input, short-circuit input with detection, voltage input |
| Short circuit mode | 3.3V voltage, short contact trigger, no linkage line monitoring function |
| Short-circuit mode with detection | 3.3V voltage, short contact trigger, support linkage line fault alarm |
| Cooling method | Air-cooled |
| Dimensions (L x D x H) | 484×4 65.1 × 100.5 mm |
| Weight | About 7.3kg |