T-8846
Controller
Learn more
Description:
The network power amplifier is installed in the weak-current room or sub-control room of each broadcast management area. It has a built-in digital power amplifier and is used for program playback and local broadcasting in halls, corridors, outdoor areas and other areas.
Features:
| Network interface | Standard RJ45×2 input |
|---|---|
| Transfer rate | 100Mbps |
| Supported agreement | TCP/IP, UDP, IGMP, ICMP |
| Audio format | Supports mainstream audio formats such as MP3, WAV, FLAC, OGG, AAC, OPUS, etc. |
| Audio mode | 16-bit CD-quality sound |
| Sampling rate | 8kHz-48kHz |
| EMC alarm input level | 775mV Industrial standard 3.81mm crimping terminal |
| AUX line input level | 350mV Industrial standard 3.81mm crimping terminal |
| MIC input level | 120 mV (6.35mm single plug interface) |
| Frequency response | 80Hz-16kHz(+1/-3dB) |
| MIC frequency response | 200Hz-10k Hz (+1/-3dB) |
| LINE OUT output distortion | ≤0.1% (≤0.3% when MIC input) |
| Amplifier harmonic distortion | ≤1% |
| LINE OUT output signal-to-noise ratio | ≥73dB |
| Amplifier signal-to-noise ratio | ≥70dB |
| LINE OUT output amplitude | 1000mV Industrial standard 3.81mm crimping terminal |
| Amplifier protection circuit | Overload and short circuit protection circuit |
| Output power* | 1000 W |
| LINE OUT output impedance | 470Ω |
| 485 interface | Yes (RJ45 terminal) |
| Power consumption ** | 200 W |
| 100V constant voltage input backup | support |
| Short circuit input | Dry contact input industrial standard 3.81mm crimping terminal |
| Short circuit output | Dry contact output industrial standard 3.81mm crimping terminal |
| Operating temperature | 5℃~40℃ |
| Working environment humidity | 20%~80% relative humidity, no condensation |
| Input power | ~220V 50Hz |
| net weight | 3.9 kg |
| Dimensions (L x W x H) | 482.6× 258 × 44 mm |
| *This power is measured according to CEA-2006-B/CEA-490-A standard using 20ms pulse 1kHz sine wave at 1% total harmonic distortion ** Based on GB4943.1-2022 test method: measured at 1kHz sine wave rated load 1/8 power | |